Standard Centrifugal Pump
Our standard centrifugal pump is primarily used for circulation and transfer of clean, chemically non-aggressive water and other liquids. It is suitable for water supply and irrigation, water circulation in air conditioning systems as well as for use in auxiliary equipment.
Motor of Standard Centrifugal PumpOperating Conditions of Standard Centrifugal Pump
Delivery: up to 220m3/h
Head: up to 95m
Liquid temperature
Standard: -10℃ to 85℃ Upon request: -20℃ to 120℃
Maximum operating pressure: 12 bar(PN12)
Anti-clockwise rotation when facing pump's suction port
Impeller: AISI304/AISI316
Mechanical seal in compliance with DIN 24960
Lubricated by internal recirculation
Housing sealed by pumped liquid
Counter flange available on request
Construction Features of Standard Centrifugal Pump
Single-impeller centrifugal pump is of axial intake and radial discharge
Inlet and outlet DN conform to EN 733(ex DIN 24255) and UNI 7467
Flanges is in compliance with UNI 2236 and DIN 2532
Rear entry design (impeller, control valve and motor can be extracted without disconnecting the pump body from the pipes)
Accessories on Request
AISI 316 stainless steel or galvanised iron threaded counter flanges
Flanged tapered coupling
Pump and motor sealing gasket
List of Model- XST Series, 50HZ, 2-Pole